Data & Voice Network Cabling Installers Orlando FL
Data & Voice Cabling FAQs – Questions and Answers
Why Use Structured Cabling?
Structured cabling is the design and installation of a
cabling systems that will support multiple hardware uses
systems and be suitable for today’s needs and those of the
future. With a correctly installed system your requirements
of today and of tomorrow will be catered for and whatever
hardware you choose to add will be supported.
Cat5e / Cat6 what’s the difference?
The general difference between Cat5e cabling and Cat6
cabling is in the transmission performance, and extension of
the available bandwidth from 100 MHz for category 5e to 250
MHz for category 6. This includes better insertion loss,
near end crosstalk (NEXT), return loss, and equal level far
end crosstalk (ELFEXT). These improvements provide a higher
signal to noise ratio, allowing higher reliability for
current applications and higher data rates for future
applications.
Should CAT6 replace CAT5e?
Industry
predictions indicate that 80 to 90 present of all new
installations will be cabled with category 6. The fact that
category 6 link and channel requirements are backward
compatible to category 5e makes it very easy for customers
to choose category 6 and supersede category 5e in their
networks. Applications that worked over category 5e will
work over category 6. Cat6A and above are also taking over
specifications for new installations, especially in data
centres and Audio Visual Installations.
What is the maximum length of CAT5 – CAT5e cable?
90m for the permanent link installation and an allowance for
10m of patch cords at the ends combined.
What’s the maximum distance between cabinet and
data points for Cat5e / Cat6?
The maximum is 90m
between the patch panel and the data point.
What factors will affect the performance of Cat5e
and CAT6cable?
Poor installation, poor
terminations and inferior materials are the main issues with
performance on cabling systems. If the cable is poorly
installed and terminated then data loss and errors will be a
continuous problem, from lost data, dropped VOIP Calls and
poor Visual displays, Interference from other cables and
outside factors such as electrical, microwave, lighting and
noise will also affect the performance of the cable.
Cat7 – what is Cat7 cabling and why would I use
it
Cat7 cable has increased performance and increased
protection against outside interference. With a bandwidth of
up to 600MHZ its increase in speed potential over Cat5e /
Cat6 is considerable. Also each pair of wires (4 pairs) are
individually shielded as well as an overall shielding for
the cable itself. This provides a great protection from
outside noise and interference. It’s especially useful in
areas of high speed data transfer in large cable bundles and
within the Audio Visual Industry.
What do I need to consider in terms of structured
data cabling to future proof my business for the next 5/10
years?
The major decision is where your office will be based in the
future and what requirements you have for your systems.
Cat5e is suitable for Gigabit data and therefore suitable to
most offices. However with Large files, Audio Visual
distribution and CCTV innovations a Cat6 or Cat6a with
future proof your offices for a longer period.
Can I use CAT 5 Cable in Power over Ethernet
applications?
Cat5e and Cat6 can both effectively run POE applications up
to 90m. However due to power dissipation there is better
performance and power efficiently with Cat6a cabling running
POE devices if being incorporated into a new design.
What is a patch cable?
A patch cable
is used at the cabinet end for linking the dedicated cabling
port to the required equipment in the communications
cabinet. For example an outlet could be “patched” from the
panel to a Data Switch, Telephone Switch, CCTV Switch, WIFI
Switch Etc. The difference to standard cable is Patch cable
is stranded for flexibility, whereas standard cable is solid
copper.
Fiber optic cabling – when is it better to use
Fiber?
Fiber cable carries greater Bandwidth and over longer
distances. It is not limited by the 90/100m limit of copper
cable and has distance potential of 40km in some cases. It
also isn’t affected by noise or outside influences as are
copper cables so is a perfect solution when linking cabinets
through risers in a building. As a standard guide when
linking separate cabinet’s Fiber Optic links should be used.
What is VoIP?
Voice over Internet
Protocol (VOIP) use digital technology to send voice signals
over your cabling infrastructure. Voice is converted to a
data transmission and converted back to a voice signal at
the users end.
VOIP – can I use VOIP over my existing network?
VOIP systems require a point to point cable from the VOIP
systems to each user. If you telephone system is of the old
daisy chain wiring (i.e. one telephone wired to the next
telephone wired to the next telephone) then this will not
support a VOIP systems. Also the existing cabling needs to
be of good standard and terminated correctly and fully
tested. A poor cabling install will result in a very poor
VoIP quality call.
Disposal of old cabling – do you dispose the old
cable?
Depending on the project and the
feasibility of the current cabling we remove the old cabling
as part of the new installation. This cabling is then taken
back to be segregated and disposed / recycled as
appropriate.
Cabling for schools. Do you provide data cabling
for schools and colleges?
Yes and having been a
preferred supplier for Florida's Schools for the past 15
years we have completed in excess of 300 projects within
schools.
Do I only need 1 cable per person as I will plug
my PC into my Phone?
Some phone systems allow
you PC to access the internet down the same cable as your
phone. However you are then limited to the speed of that
phone (i.e. 100MB). Also you are limited in future options.
If you choose to pick a different system that requires a
dedicated line then you have to install all new cables. Our
recommendation is when installing to each desk install a
minimum of 2 per user (PC and Phone)
What disruption would data cable installation
cause to my company – how long will we be out of action?
If the data cabling installation is new and doesn’t require
unplugging your existing infrastructure then we can install
without and disruption. To facilitate this further we can
install on weekends or in the evening when the building is
empty to minimise disruption.
Can I get the builder to install the cable and
you terminate and test?
This is not recommended
due to the success of a cabling systems performance is its
installation and its termination. Installation requires
adherence to limited bend radius of the cables, separation
from noise interference, and correct securing and bundling
of the cable. This is part of the experience and expertise
of the cabling installation contractor.
However in practical terms sometimes the cabling needs to be installed by the builder before the client takes the building. In this scenario we can trace, terminate and test the system but can’t guarantee the results will pass.
What do Data cable installation test results
show?
Test Results show a range of tests depending on the grade of
cabling used (Cat5e / Cat6 etc.). These tests for Cat6
include Wire Map, Length, Insertion Loss, NEXT Loss, PS NEXT
Loss, ACRF Loss, PS ACRF Loss, Return Loss, Propagation
Delay, Delay Skew. These are tests to ensure installation
standards have been met, the terminations have been done
correctly and that the cable doesn’t have any unnecessary
bends, kinks and twists.
Do I need a cabinet, can’t I just plug straight
into my equipment?
A cabinet is always
recommended even for the smallest installs. Cabling plugged
directly into equipment has a tendency to break away at the
termination ends as solid cable is not suitable for direct
termination. Also a cabinet provides protection for the
equipment from theft, breakage, dust and employees. Cabinets
also allow all the equipment to be stored together and in a
manageable way for moves and changes.
Why do I need such a big cabinet?
The
cabinet should be large enough to house the current
equipment with some space for possible future requirements.
I.e. for a VOIP telephone system to be housed. The depth of
the cabinet should keep in mind what is to be stored in the
cabinet. Some ISP switches and blade servers are extra deep
and required a 800/1000mm deep cabinet.
Why do you use LSOH (Low Smoke zero Halogen)
cable on our installations?
Most network cables
are insulated with polyethylene, PVC or thermoplastic
polyurethane. In a fire, a chlorine containing plastic
material releases hydrogen chloride, a poisonous gas that
forms hydrochloric acid when it comes in contact with water.
Low smoke zero halogen cable reduces the amount of toxic and
corrosive gas emitted during combustion.
Do you charge for an initial survey?
Initial surveys are free as are introductory meetings for
design. However visits to explore faults etc. that require
an engineer are charged at call out rates.
What times are your normal working hours for
engineers?
Our normal working day is Monday – Friday between 8-5, but
we can also work before/after these hours if required. In
many cases out of hours working is charged at the same rates
depending on requirements, location and hours.
Do you charge extra for weekend and evening work?
In many cases we offer weekend working at the same rates as
normal hours. This depends on location, requirements and
hours. Evenings depend on how many evenings will run in
succession.
More questions on Data Cabling?
Just
give us a call. Or take advantage of our free Data Cabling
survey –we offer expert advice to clients planning to set
up, upgrade or expand data cable installations – just drop
us a line or call.