Structured Cabling & Wiring Contractors
Voice & Data Cabling Glossary
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
A
Absorption
The loss of light energy
in an optical fiber resulting from impurities in the glass.
Acceptance Cone
A cone angled area
that light must enter in order to "bounce" down the fiber,
or travel between the core and the cladding.
Acrylate
Acrylic resin.
Adapter
A mechanical media
termination device designed to align and join fiber optic
connectors. Often referred to as a coupling, bulkhead, or
interconnect sleeve.
All-dielectric
Non-conducting; made
entirely of dielectric (insulating) materials, without any
metal conductors.
Analog
A format that uses continuous
physical variables such as voltage amplitude or frequency
variations to transmit information.
Aramid Yarn
Strength elements that
provide tensile strength and provides support and additional
protection of the fiber bundles. Kevlar® is a particular
brand of aramid yarn.
Armor
Additional protective element
beneath outer jacket to provide protection against severe
outdoor environments. Usually made of plastic-coated steel,
it may be corrugated for flexibility.
Attenuation
The decrease in magnitude
of power of a signal in transmission between points. A term
used for expressing the total loss of an optical system,
normally measured in decibels (dB) at a specific wavelength.
Attenuation Coefficient
The rate of
optical power loss with respect to distance along the fiber,
usually measured in decibels per kilometer (dB/km) at a
specific wavelength. The lower the number, the better the
fiber's attenuation. Typical multimode wavelengths are 850
and 1300 nanometers (nm); single mode wavelengths are 1310
and 1550 nm. Note: When specifying attenuation, it is
important to note whether the value is average or nominal.
[Back to Top]
B
Backbone Cabling
The portion of
premises telecommunications cabling that provides
connections between telecommunications closets, equipment
rooms, and entrance facilities. The backbone cabling
consists of the transmission media (optical fiber cable),
main and intermediate cross-connects, and terminations for
the horizontal cross-connect, equipment rooms, and entrance
facilities. The backbone cabling can further be classified
as inter-building backbone (cabling between buildings), or
intrabuilding backbone (cabling within a building).
Bandwidth
Measure of the
information-carrying capacity of an optical fiber. Note:
This term is often used to specify the normalized modal
bandwidth (MHz·km) of a multimode fiber. See Dispersion for
single-mode fibers.
Bandwidth-Distance Product
The
information-carrying capacity of a transmission medium is
normally referred to in units of MHz·km. This is called the
bandwidth-distance product or, more commonly, bandwidth. The
amount of information that can be transmitted over any
medium
changes according to distance. The relationship is
not linear,
however. A 500 MHz·km fiber does not
translate to 250 MHz for
a 2 kilometer length or 1000 MHz
for a 0.5 kilometer length. It is
important, therefore,
when comparing media, to ensure that the
same units of
distance are being used.
Broadband
Typically referring to
copper, it denotes transmission facilities
capable of
handling a wide range of frequencies simultaneously, thus
permitting multiple channels in data systems, rather than
direct
modulation.
Buffering
(1) A protective material
extruded directly on the fiber coating to
protect it from
the environment (tight-buffered); (2) extruding a tube
around the coated fiber to allow isolation of the fiber from
stresses
in the cable (buffer tubes).
Buffer Tubes
Extruded cylindrical
tubes covering optical fiber(s) used for
protection and
isolation. See Loose Tube.
Bundle
Many individual fibers
contained within a single jacket or buffer
tube. Also, a
group of buffered fibers distinguished in some fashion
from another group in the same cable core.
[Back to Top]
C
Cable
An assembly of optical fibers
and other material providing
mechanical and environmental
protection.
Cable Assembly
Optical fiber cable
that has connectors installed on one or both
ends.
General use of these cable assemblies includes the
interconnection of optical fiber cable systems and
opto-electronic
equipment. If connectors are attached to
only one end of a cable, it
is known as a pigtail. If connectors are attached to both
ends, it is
known as a jumper or patch cord.
Cable Bend Radius
Cable bend radius
during installation infers that the cable is
experiencing
a tensile load. Free bend infers a smaller allowable
bend
radius since it is at a condition of no load.
Central Member
The center component
of a cable. It serves as an antibuckling
element to
resist temperature-induced stresses. Sometimes serves
as
a strength element. The central member material is either
steel,
fiberglass, or glass-reinforced plastic.
Centralized Cabling
A cabling
topology used with centralized electronics connecting the
optical horizontal cabling with intrabuilding backbone
cabling
passively in the telecommunications closet.
Cladding
The material surrounding the
core of an optical waveguide. The
cladding must have a
lower index of refraction to keep the light in
the core.
Coating
A material put on a fiber
during the draw process to protect it from
the
environment and handling.
Composite Cable
A cable containing
both fiber and copper media per article 770 of
the
National Electrical Code (NEC).
Conduit
Pipe or tubing through which
cables can be pulled or housed.
Connecting Hardware
A device used to
terminate an optical fiber cable with connectors
and
adapters that provides an administration point for
cross-connecting between cabling segments or interconnecting
to
electronic equipment.
Connector
A mechanical device used to
align and join two fibers together to
provide a means for
attaching to and decoupling from a transmitter,
receiver,
or another fiber (patch panel). Commonly used
connectors
include the 568SC (Duplex SC), ST® compatible,
FDDI,
ESCON, SMA 905/906, Biconic, FC, or D4.
Connector Panel
A panel designed for
use with patch panels; it contains either 6, 8,
or 12
adapters pre-installed for use when field-connectorizing
fibers.
Connector Panel Module
A module
designed for use with patch panels; it contains either 6 or
12 connectorized fibers that are spliced to backbone cable
fibers.
Consolidation
The second
manufacturing step in the OVD process; manufacturing
step
which removes water vapor from the preform, and sinters it
into a solid, dense, transparent glass blank.
Core
The central region of an optical
fiber through which light is
transmitted.
Coupling
See Adapter.
[Back to Top]
D
Decibel (dB)
Unit for measuring the
relative strength of light signals. Normally
expressed in
dB, it is equal to one-tenth the common logarithm of
the
ratio of the two levels. Expressed in dBm when a power level
is
compared to a milliwatt.
Dielectric
Non-metallic and,
therefore, non-conductive. Glass fibers are
considered
dielectric. A dielectric cable contains no metallic
components.
Digital
A data format that uses two
physical levels to transmit information
corresponding to
0s and 1s. A discrete or discontinuous signal.
Dispersion
The cause of bandwidth
limitations in a fiber. Dispersion causes a
broadening of
input pulses along the length of the fiber. Three major
types are: (1) modal dispersion caused by differential
optical path
lengths in a multimode fiber; (2) chromatic
dispersion caused by a
differential delay of various wavelengths of light in a
waveguide
material; and (3) waveguide dispersion caused by light
traveling in
both the core and cladding materials in
single-mode fibers.
Draw
The third and final step in the
OVD process; draws the glass blank
into a continuous
strand of glass fiber.
[Back to Top]
E
Entrance Facility
An entrance to a
building for both public and private network
service
cables including the entrance point at the building wall and
continuing to the entrance room or space.
Equipment Room
A centralized space
for telecommunications equipment that serves
the
occupants of a building. An equipment room is considered
distinct from a telecommunications closet because of the
nature or
complexity of the equipment.
Extrinsic
External; outside the
fiber.
[Back to Top]
F
FOTP
Fiber Optic Test Procedures.
Defined in TIA/EIA Publication
Series 455.
Fan-Out
Siecor multifiber cable
constructed in the tight-buffered design.
Designed for
ease of connectorization and rugged applications for
intra- or interbuilding requirements.
Ferrule
A mechanical fixture,
generally a rigid tube, used to protect and
align a fiber
in a connector. Generally associated with fiber optic
connectors.
Fiber
Thin filament of glass. An
optical waveguide consisting of a core
and a cladding
that is capable of carrying information in the form of
light.
Fiber Bend Radius
Radius a fiber can
bend before the risk of breakage or increase in
attenuation.
Fiber Distributed Data Interface (FDDI)
A standard for a 100 Mbit/s fiber optic local area network.
Fiber Optics
Light transmission
through optical fibers for communication or
signaling.
Fresnel Reflection Losses
Reflection
losses that are incurred at the input and output of optical
fibers due to the differences in refraction index between
the core
glass and immersion medium.
Frequency
The number of pulses or
cycles per second; measured in units of
Hertz (Hz) where
1 hertz equals 1 pulse/cycle per second.
Fusing
The actual operation of
joining fibers together by fusion or by
melting.
Fusion Splicing
A permanent joint
produced by the application of localized heat
sufficient
to fuse or melt the ends of the optical fiber, forming a
continuous single fiber.
[Back to Top]
G
Gigahertz (GHz)
A unit of frequency
that is equal to one billion cycles per second,
109
Hertz.
Graded-Index
Fiber design in which
the refractive index of the core is lower
toward the
outside of the fiber core and increases toward the center
of the core; thus, it bends the rays inward and allows them
to travel
faster in the lower index of refraction region. This type of
fiber
provides higher bandwidth capabilities for
multimode fiber
transmission.
[Back to Top]
H
Hertz (Hz)
The frequency in
pulses/cycles per second where 1 hertz equals 1
pulse/cycle per second.
Horizontal Cabling
That portion of
the telecommunications cabling that provides
connectivity
between the horizontal cross-connect and the
work-area
telecommunications outlet. The horizontal cabling
consists of transmission media, the outlet, the terminations
of the
horizontal cables, and horizontal cross-connect.
Horizontal Cross-Connect (HC)
A
cross-connect of horizontal cabling to other cabling, e.g.,
horizontal, backbone, equipment.
Hybrid Cable
A fiber optic cable
containing two or more different types of fiber,
such as
62.5 µm multimode and single-mode.
[Back to Top]
I
IEEE
Institute of Electrical and
Electronics Engineers.
Index-Matching Fluid
A fluid with an
index of refraction close to that of glass that reduces
reflections caused by refractive-index differences.
Index of Refraction (IOR)
The ratio
of light velocity in a vacuum to its velocity in a given
transmission medium.
Interbuilding Backbone
The portion of
the backbone cabling between buildings. See
Backbone
Cabling.
Intermediate Cross-Connect (IC)
A
secondary cross-connect in the backbone cabling used to
mechanically terminate and administer backbone cabling
between
the main cross-connect and horizontal
cross-connect.
Intrabuilding Backbone
The portion of
the backbone cabling within a building. See
Backbone
Cabling.
Intrinsic
Inherent; within; inside
the fiber.
[Back to Top]
J
Jumper
Optical fiber cable that has
connectors installed on both ends. See
Cable Assembly.
[Back to Top]
K
kpsi
A unit of force per area
expressed in thousands of pounds per
square inch. Usually
used as the specification for fiber proof test,
e.g., 100
kpsi.
Kevlar
See Aramid Yarn.
Kilometer (km)
One thousand meters,
or approximately 3,281 feet, or 0.62 miles.
The kilometer
is a standard unit of length measurement in fiber
optics.
Conversion is 1 ft. = 0.3048 m.
[Back to Top]
L
LAN
See Local Area Network.
LASER Diode
Light Amplification by
Stimulated Emission of Radiation. An
electro-optic device
that produces coherent light with a narrow
range of
wavelengths, typically centered around 780 nm, 1310 nm,
or 1550 nm. Lasers with wavelengths centered around 780 nm
are
commonly referred to as CD Lasers.
Laydown
The first step of fiber
manufacturing using the OVD process;
deposition of
ultrapure vapors around a rotating target rod to form
a
glass preform.
Light Emitting Diode (LED)
A
semiconductor device used to transmit light into a fiber in
response to an electrical signal. It typically has a broad
spectral
width.
Link
A telecommunications circuit
between any two telecommunications
devices, not including
the equipment connector.
Local Area Network (LAN)
A
geographically limited communications network intended for
the
local transport of voice, data, and video. Often
referred to as a
customer premises network.
Loose Tube Cable
Type of cable design
whereby coated fibers are encased in buffer
tubes
offering excellent fiber protection and segregation.
[Back to Top]
M
MDPE
Abbreviation used to denote
medium density polyethylene. A type
of plastic material
used to make cable jacketing.
Macrobend
A large cable bend that can
be seen with the unaided eye; often
reversible.
Main Cross-Connect (MC)
The
centralized portion of the backbone cabling used to
mechanically terminate and administer the backbone cabling,
providing connectivity between equipment rooms, entrance
facilities, horizontal cross-connects, and intermediate
cross-connects.
Mechanical Splicing
Joining two
fibers together by permanent or temporary mechanical
means (vs. fusion splicing or connectors) to enable a
continuous
signal. The CamSplice is a good example of a
mechanical splice.
Megahertz (MHz)
A unit of frequency
that is equal to one million cycles per second.
Meter
A decimal unit of measure
equaling 3.28 feet.
Microbend
A small, microscopic bend
which may be caused by the cabling
process; mechanical
stress due to water in the cable during
repeated freeze
and thaw cycles, packaging, or installation.
Micrometer (µm)
One millionth of a
meter; 10-6 meter. Typically used to express the
geometric dimension of fibers, e.g., 62.5 µm.
Mini Bundle® Cable
Siecor loose tube
cable in which the buffer tube contains two or
more
fibers, typically 6 or 12 fibers.
Minimum Bend Radius
The amount of
bend a fiber (or cable) can withstand before
experiencing
problems in performance.
Mode
A term used to describe an
independent light path through a fiber,
as in multimode
or single-mode.
Mode Field Diameter
The diameter of
the one mode of light propagating in a single-mode
fiber.
The mode field diameter replaces core diameter as the
practical parameter in single-mode fiber.
Modulation
Coding of information onto
the carrier frequency. This includes
amplitude,
frequency, or phase modulation techniques.
Multifiber Cable
An optical fiber
cable that contains two or more fibers.
Multimode Fiber (MM)
An optical
waveguide in which light travels in multiple modes.
Typical core/cladding size (measured in micrometers) is
62.5/125.
Multiplex
Combining two or more
signals into a single bit stream that can be
individually
recovered.
Multi-User Outlet
A
telecommunications outlet used to serve more than one work
area, typically in open-systems furniture applications.
[Back to Top]
N
National Electrical Code (NEC)
Defines building flammability requirements for indoor
cables. Note:
Local codes take precedence but may refer to or require
compliance to the NEC.
Nanometer (nm)
A unit of measurement
equal to one billionth of a meter; 10-9
meters. Typically
used to express the wavelength of light, e.g., 1300
nm.
Numerical Aperture (NA)
The number
that expresses the light gathering ability of a fiber.
Related to acceptance angle.
[Back to Top]
O
Optical Fiber
See Fiber.
Optical Time Domain Reflectometer (OTDR)
An instrument that measures transmission characteristics by
sending
a series of short pulses of light down a fiber
and providing a graphic
representation of the
backscattered light.
Outside Vapor Deposition (OVD)
An
optical fiber manufacturing method developed, patented, and
used by Corning; manufacturing method using three steps:
laydown,
consolidation, and draw.
[Back to Top]
P
PE
Abbreviation used to denote
polyethylene. A type of plastic
material used for outside
plant cable jackets.
PVC
Abbreviation used to denote
polyvinyl-chloride. A type of plastic
material used for
cable jacketing. Typically used in flame-retardant
cables.
PVDF
Abbreviation used to denote
polyvinyl-difluoride. A type of material
used for cable
jacketing. Often used in plenum-rated cables.
Pigtail
Optical fiber cable that has
a connector installed on one end. See
Cable Assembly.
PIN Diode
A semiconductor device used
to convert optical signals to electrical
signals in a
receiver.
Plenum
An air-handling space such as
that found above drop-ceiling tiles or
in raised floors.
Also, a fire-code rating for indoor cable.
Point-to-Point
A connection
established between two specific locations as
between two
buildings.
Prefusing
Fusing with a low current
to clean the fiber end. Precedes fusion
splicing.
[Back to Top]
Q
Rr
RH
Relative humidity.
Receiver
An electronic package that
converts optical signals to electrical
signals.
Reflectance
Reflectance is the ratio
of power reflected to the incident power at
a connector
junction or other component or device, usually
measured
in decibels or dB. Reflectance is stated as a negative
value, e.g., -30 dB. A connector that has a better
reflectance
performance would be a -40 dB connector or a
value less than -30
dB. The terms return loss, back
reflection, and reflectivity are also
used synonymously
in the industry to describe device reflections,
but
stated as positive values.
Repeater
A device used to regenerate
an optical or electrical signal to allow
an increase in
the system length.
Return Loss
See Reflectance.
Riser
Pathways for indoor cables that
pass between floors. It is normally
a vertical shaft or
space. Also a fire-code rating for indoor cable.]
[Back to Top]
S
Scattering
A property of glass that
causes light to deflect from the fiber and
contributes to
optical attenuation.
Single-Mode Fiber (SM)
An optical
waveguide (or fiber) in which the signal travels in one
mode. The fiber has a small core diameter, typically 8.3 µm.
Splice Closure
A container used to
organize and protect splice trays. Typically
used in
outside plant environments.
Splice Tray
A container used to
secure, organize, and protect spliced fibers.
Splicing
The permanent joining of
bare fiber ends to another fiber. See
Fusion Splice and
Mechanical Splicing.
[Back to Top]
T
Telecommunications Closet (TC)
An
enclosed space for housing telecommunications equipment,
cable terminations, and cross-connects. The closet is the
recognized
cross-connect between the backbone and
horizontal cabling.
Tensile
Pulling (strength or stress).
Termination
A connection.
Tight-Buffered Cable
Type of cable
construction whereby each glass fiber is tightly
buffered
by a protective thermoplastic coating to a diameter of 900
micrometers. Increased buffering provides ease of handling
and
connectorization.
Total Internal Reflection
Reflection
that occurs when a light ray traveling in one material hits
another material and reflects back into the original
material without
any loss of light.
Transmitter
An electronic package
used to convert an electrical
information-carrying signal
to a corresponding optical signal for
transmission by
fiber. The transmitter is usually a Light Emitting
Diode
(LED) or Laser Diode.
[Back to Top]
U
UL
Underwriters Laboratories, Inc.
[Back to Top]
V
Video
Video cameras and cable
television.
Visible spectrum
The portion of the
electromagnetic spectrum that can be seen by the
unaided
human eye.
Voice
Telephone services.
[Back to Top]
W
Wavelength
The distance between two
successive points of an electromagnetic
waveform, usually
measured in nanometers (nm).
Window
A range of wavelengths within
which a fiber best operates.
Work-Area Telecommunications Outlet
A
connecting device located in a work area at which the
horizontal
cabling terminates and provides connectivity for work-area
patch
cords.
[Back to Top]
X
Y
Z
Zero-Dispersion Wavelength
Wavelength
at which the chromatic dispersion of an optical fiber is
zero. Occurs when waveguide dispersion cancels out material
dispersion.